Stack Monitoring

Stack Emission Monitoring is done for measurement of common pollutants that are emitted out of processes and fuel burning.

This helps to assess pollution, check status of manufacturing equipments, pollution control equipments, statutory compliances, internal audit, save fuel, improve efficiency of manufacturing equipments, save money by saving on wastages, improvement environment and better working environment.
A sampling hole of Dia. 150mm has to be provided on the stack, about 6 to 8 times the Dia. of the stack after the entry gas entry point and about 2 times the Dia. of the stack before the end point.

  

A working platform of 1x1.5m capable of taking load of 500 kg (2 persons) is required to be provided. Single Phase electrical supply of 230 V is required for the monitoring instruments. The sampling exercise takes about 3 to 4 hours time for each stack for drawing Suspended Particulate Matter and common gaseous pollutants. The process has to stable and in normal operation.

Stack Monitoring Kit is used to measure Temperature, Velocity of gases and Pressure inside the stack. This is essential for carrying out proper representative sampling at iso-kinetic conditions. Some quick calculations on site enable us to decide the sampling rate for Suspended Particulate Matter (SPM). The SPM sample is filtered in a thimble firmly held in a thimble holder. This is pre-weighed and post weighed in laboratory in a balance accurate up to 0.0001gm to determine gravimetrically the SPM collected. Using the sampling rate and the duration of sampling, concentration of SPM in emissions is calculated in terms of milli-gram/Nm3, which is a standardized gas volume at 250C.

Gases are sampled in appropriate absorbing solutions kept in impinger tubes. These are then analyzed in the laboratory as per standard respective method.

The results are made available within 2-3 days after the sampling is over. The report is given in standard format indicating all monitoring values (3 copies).

 


Information Request Form

Select the items that apply, and then let us know how to contact you.

Send service literature
Send company literature
Have a salesperson contact me

Name
Title
Company
Address
E-mail
Phone

 

Home ] Up ]

Send mail to mahabal@bom2.vsnl.net.in with questions or comments about this web site.
Copyright © 2003 Mahabal Enviro Engineers Pvt. Ltd.
Last modified: 11/24/03