This helps to assess pollution, check
status of manufacturing equipments, pollution control equipments, statutory
compliances, internal audit, save fuel, improve efficiency of
manufacturing equipments, save money by saving on wastages, improvement
environment and better working environment.
A sampling hole of Dia. 150mm has to be provided on the stack, about 6 to 8
times the Dia. of the stack after the entry gas entry point and about 2
times the Dia. of the stack before the end point. |
|
Stack Monitoring Kit is used to measure Temperature, Velocity
of gases and Pressure inside the stack. This is essential for carrying out
proper representative sampling at iso-kinetic conditions. Some quick
calculations on site enable us to decide the sampling rate for Suspended
Particulate Matter (SPM). The SPM sample is filtered
in a thimble firmly held in a thimble holder. This is pre-weighed and post
weighed in laboratory in a balance accurate up to 0.0001gm to
determine gravimetrically the SPM collected. Using the sampling rate and the
duration of sampling, concentration of SPM in emissions is calculated in
terms of milli-gram/Nm3, which is a standardized gas volume at 250C.
Gases are sampled in appropriate absorbing solutions kept in
impinger tubes. These are then analyzed in the laboratory as per standard
respective method.
The results are made available within 2-3 days after the
sampling is over. The report is given in standard format indicating all
monitoring values (3 copies). |