This
helps to assess pollution, check status of manufacturing
equipments, pollution control equipments, statutory
co<>mpliances, internal audit, save fuel, improve
efficiency of manufacturing equipments, save money
by saving on wastages, improvement environment
and better working environment.
A sampling hole of Dia. 150mm has to be provided
on the stack, about 6 to 8 times the Dia. of the
stack after the entry gas entry point and about
2 times the Dia. of the stack before the end point.
|
|
Stack
Monitoring Kit is used to measure Temperature,
Velocity of gases and Pressure inside the stack.
This is essential for carrying out proper representative
sampling at iso-kinetic conditions. Some quick
calculations on site enable us to decide the sampling
rate for Suspended Particulate Matter (SPM). The
SPM sample is filtered in a thimble firmly held
in a thimble holder. This is pre-weighed and post
weighed in laboratory in a balance accurate up
to 0.0001gm to determine gravimetrically the SPM
collected. Using the sampling rate and the duration
of sampling, concentration of SPM in emissions
is calculated in terms of milli-gram/Nm3, which
is a standardized gas volume at 250C.
Gases
are sampled in appropriate absorbing solutions
kept in impinger tubes. These are then analyzed
in the laboratory as per standard respective method.
The
results are made available within 2-3 days after
the sampling is over. The report is given in standard
format indicating all monitoring values (3 copies).
|